166
MVP MANUAL
(12) Full dot number compensation [HFD command]Input : HFDddd
Explanation :• d1d2d3:Compensation data 0 to 254
•Corrects the preset sampling clock.
•Vertical bit lines can be erased by executing the HFD command.
•The HFD and HPS data are correlated and have limited values.
Bit lines
Figure: Bit Lines which can be Erased by HFD Execution
(13) Freeze frame Y:ON N:OFF [FZY, FZN commands]Input : FZY, FZN
Explanation :• Continuously outputs the image the moment the FZY is executed. This is canceled by FZN.
•Whether the state is FZY or FZN can be determined by executing the STS command.
•Do not perform position adjustments in the FZY state.
(14) Vertical filter ON/OFF [DSY, DSN, DSX commands]Input : DSY, DSN, DSX
Explanation :• Converts the vertical line number so that the computer images can be displayed fully on the
monitor.
•The conversion rate preset by the LCV command can be changed. (Refer to LCV command.)
•Whether the state is DSY or DSN can be determined by executing the STS command.
DSY
DSN
Figure: Example of DSY and DSN Executions (MAC 6-5 Conversion Example)
•The DSX is a command which makes the V.FIL switch on the rear of the MVP effective.
400 vertical lines
480 vertical lines