167
MVP MANUAL
(15) Vertical compression filter conversion rate input [LCV command]Input : LCVd1d2d3d4
Explanation :• d1d2=00 to 15 (Add 0 before all numbers below 9) Vertical direction rate before conversion
•d
3d4=00 to 15 (Add 0 before all numbers below 9) Vertical direction rate after conversion
Due to the use of a compression filter, the condition is d1d2 > d3d4.
Both LCV0000 and LCV0101 are not convertible.
•Directly changes the vertical filter conversion rate of the data table of the model using the VS
board currently.
•When the conversion rate is changed for DSY, the image compressed by the new conversion rate
will be output.
(Example)
: LCV0605 Set 6–>5 conversion
(16) Program ROM version display [VER command]Input : VER
Explanation :• Indicates the version of the program ROM mounted in the current VS board.
(Example)
: VER
PROGRAM VERSION=BXY1004-X VX.XX 199X.XX.XX
(17) To indicate the current function setting [STS command]Input : STS
Explanation :• Displays the model data No., selected state (auto or forced), vertical filter ON, OFF, and freeze
ON, OFF selected by the VS board currently.
(Example)
: STS
STATUS=DSY, FZN
MODEL NO.=09 AUTO
: STS
STATUS=DSY, FZN
MODEL NO.=03 FIXED
=
Autolocks to PC9801 with the left display, indicates vertical
filter ON, freeze OFF.
Forcible locks the Macintosh with the left display, indicates
vertical filter ON, freeze OFF.