4 Charging

 

 

 

 

 

 

 

 

 

Partially discharging the BP 4000 many times may reduce its capacity (memory effect) or

4.6 Recovery Cycle

affect the accuracy of the remaining-capacity display.

 

 

The recovery cycle performed by the CU 4000 charger reduces the memory effect and re -

 

 

stores the accuracy of the remaining-capacity display.

 

 

After approx. every 16 partial-discharge cycles, the device display will indicate "Err.Acc" and

 

 

"--.-" instead of the hour display. (The remaining battery capacity will only be indicated by

 

 

the bar graph.) Once you insert the device into the charger, the RECOVER LED will start

 

 

flashing orange.

 

 

These messages request you to start a recovery cycle as soon as possible. The charger will

 

 

not perform a recovery cycle before you have pressed the RECOVER key for at least 3 sec-

 

 

onds.

 

 

• In most cases, the "Err.Acc" or “Rec.Acc” message in the device display is only a re-

Note:

quest to perform a recovery cycle rather than an error message!

 

 

However, if the "Err.Acc" message comes up again when you power the device up after a successful recovery cycle (the RECOVER LED will not flash orange on inserting the device), there may be a communication problem between the device and the BP 4000. In this case, please contact your nearest AKG Service Center.

CHARGE

RECOVER

Status

Action

 

 

 

 

orange

---

The inserted device

---

 

 

is being checked.

 

 

 

The test takes about

 

 

 

4 to 10 seconds.

 

 

 

 

 

red

>orange<

The BP 4000 is

Press and hold the

 

 

being charged, and

RECOVER key next

 

 

a recovery cycle is

to the flashing

 

 

recommended.

RECOVER LED.

 

 

 

 

red

>green<

The BP 4000 is

Hold the RECOVER

 

 

being charged and

key down for at

 

 

the RECOVER LED

least 3 seconds.

 

 

indicates the

 

 

 

RECOVER key is

 

 

 

being held down.

 

 

 

 

 

red

red

The recovery cycle

Release the

 

 

has started. The

RECOVER key.

 

 

BP 4000 is charged

 

 

 

for a few minutes if

 

 

 

required.

 

 

 

 

 

>red/orange<

red

Recovery cycle: the

---

 

 

BP 4000 is being

 

 

 

discharged.

 

 

 

 

 

red

red

Recovery cycle: the

---

 

 

BP 4000 is being

 

 

 

charged for the first

 

>red/orange<

red

time.

 

 

 

 

 

 

 

Recovery cycle: the

---

 

 

BP 4000 is being

 

 

 

discharged.

 

 

 

 

 

Table 4: Recovery cycle

CU 4000

23

Page 23