MAINTENANCE
MOTOR & COUPLING INSTALLATION
Bolt motor to mount plate. Fully tighten bolt (Item 1).
Install flex coupler to the quick disconnect pulley hub using the countersunk socket head bolts (Item 2). Apply thread locking compound to the bolts. Tighten bolts to 45
Insert motor shaft into flex coupling and allow motor to "find its center."
Adjust motor up as needed to provide ample clearance between the top of flex coupling and the motor. Bring angle brackets up to motor mount plate and tighten the bolts.
SAMURAI 12/08 | Maintenance Section |