VIP X1600 M4SInstallation en 21
Relay Outputs
The module has four relay outputs for switching external units such as lamps or alarm sirens. You can operate these relay outputs manually while there is an active connection to the module. The outputs can also be configured to automatically activate sirens or other alarm units in response to an alarm signal. The relay outputs are also located on the orange terminal block (see Section 8.8 Terminal Block, page 107).
! | CAUTION! |
A maximum load of 30 V and 2 A may be applied to the relay contacts. | |
| |
|
|
| X Connect the lines to the appropriate terminals on the orange terminal block (R1 to R4) |
| and check that the connections are secure. |
4.4 | Setup Using the Configuration Manager |
| The Configuration Manager program can be found on the product CD contained in the |
| VIP X1600 XF base's scope of delivery. This program allows you to implement and set up new |
| modules quickly and conveniently. |
|
|
i | NOTICE! |
Using the Configuration Manager to set all parameters in the module is an alternative to | |
configuration by means of a Web browser, as described in chapter 5 of this manual. | |
|
|
Installing the Program
1.Insert the CD into the computer's
2.If the CD does not start automatically, open the Configuration Manager directory using Windows Explorer and
3.Follow the
Bosch Security Systems | Installation and Operating Manual | DOC V4.0 2009.06 |