106 en AppendixVIP X1600 M4S
8.3 | Malfunctions with iSCSI Connections |
| ||
|
|
|
|
|
|
| Malfunction | Possible causes | Recommended solution |
|
|
|
|
|
|
| After connecting to the | Incorrect LUN mapping during | Check the iSCSI system |
|
| iSCSI destination, no | iSCSI system configuration. | configuration and reconnect. |
|
| LUNs are displayed. |
|
|
|
|
|
|
|
|
| After connecting to the | The LUN list could not be read, | Check the iSCSI system |
|
| iSCSI destination, "LUN | as it was assigned to the wrong | configuration and reconnect. |
|
| FAIL" appears below a | network interface. |
|
|
| node. |
|
|
|
|
|
|
|
|
| LUN mapping is not | Some iSCSI systems do not | Delete the initiator extension on |
|
| possible. | support the use of an initiator | the Identification configuration |
|
|
| extension. | page. |
|
|
|
|
|
8.4 | LEDs |
| The VIP X1600 XF network video server is equipped with a number of LEDs that show the |
| operating status and can give indications of possible malfunctions. |
| RJ45 Sockets 10/100/1000 |
Green LED lights up: | 10 MB network connection established. |
Green LED flashes: | Data transmission via 10 MB network connection. |
Green and orange LEDs light up: | 100 MB network connection established. |
Green and orange LEDs flash: | Data transmission via 100 MB network connection. |
Orange LED lights up: | 1 GB network connection established. |
Orange LED flashes: | Data transmission via 1 GB network connection. |
SFP |
|
Does not light up: | No connection. |
Lights up yellow: | Connection established. |
Flashes yellow: | Data being transmitted. |
Module 1 / Module 2 / Module 3 / Module 4 | |
Does not light up: | Slot not occupied. |
Lights up green: | Module is switched on. |
Flashes green: | The module is being accessed. |
Flashes red: | Startup in progress. |
Lights up red: | Module is faulty, for example following failed firmware |
| upload. |
Power/Fail
Does not light up: Lights up green: Flashes red:
VIP X1600 XF is switched off.
Startup complete, VIP X1600 XF is operational. Defect in fans or redundant power supply unit.
DOC V4.0 2009.06 | Installation and Operating Manual | Bosch Security Systems |