Bosch Appliances VIP X1600 M4S manual Video transmission, Remote port, Video output, Decoder

Models: VIP X1600 M4S

1 124
Download 124 pages 32.66 Kb
Page 57
Image 57

VIP X1600 M4S

Configuration Using a Web Browser en 57

 

 

module can use this general password to connect to all remote stations protected with the same password. In this case, proceed as follows:

1.Select 10 from the Number of destination IP address list field.

2.Enter the address 0.0.0.0 in the Destination IP address field.

3.Enter your chosen password in the Destination password field.

4.Define this password as the user password for all remote stations to which a connection is to be possible.

NOTICE!

i

If you enter the destination IP address 0.0.0.0 for destination 10, this module address will no

 

 

longer be used for the tenth attempt at automatic connection in the event of an alarm. The

 

parameter is then used only to save the general password.

 

 

 

Video transmission

 

If the VIP X1600 XF is operated behind a firewall, TCP (HTTP port) should be selected as the

 

transfer protocol. For use in a local network, select UDP.

 

 

 

CAUTION!

!

Please note that in some circumstances, a larger bandwidth must be available on the network

for additional video images in the event of an alarm, in case Multicast operation is not

possible. To enable Multicast operation, select the UDP option for the Video transmission

 

parameter here and on the Network page (see Section Video transmission, page 75).

 

 

 

Remote port

 

Depending on the network configuration, select a browser port here. The ports for HTTPS

 

connections will be available only if the On option is selected in the SSL encryption

 

parameter.

 

Video output

 

If you know which unit is being used as the receiver, you can select the analog video output to

 

which the signal should be switched. If the destination unit is unknown, it is advisable to

 

select the First available option. In this case, the image is placed on the first free video

 

output. This is an output on which there is no signal. The connected monitor only displays

 

images when an alarm is triggered. If you select a particular video output and a split image is

 

set for this output on the receiver, you can also select from Decoder the decoder in the

 

receiver that is to be used to display the alarm image.

 

 

i

NOTICE!

Refer to the destination unit documentation concerning image display options and available

video outputs.

 

 

 

Decoder

 

Select a decoder of the receiver to display the alarm image. The decoder selected has an

 

impact on the position of the image in a split screen. For example, you can specify via a VIP XD

 

that the upper-right quadrant should be used to display the alarm image by selecting

 

decoder 2.

 

SSL encryption

 

The data for the connection, for example the password, can be securely transmitted with SSL

 

encryption. If you have selected the On option, only encrypted ports are offered in the

 

Remote port parameter.

Bosch Security Systems

Installation and Operating Manual

DOC V4.0 2009.06

Page 57
Image 57
Bosch Appliances VIP X1600 M4S manual Video transmission, Remote port, Video output, Decoder, SSL encryption