VIP X1600 M4S

Configuration Using a Web Browser en 63

 

 

high value if fewer sensor fields need to change to trigger an alarm. With a low value, it is necessary for changes to occur simultaneously in a large number of sensor fields to trigger an alarm.

This option allows you to detect, independently of motion alarms, manipulation of the orientation or location of a camera resulting from turning the camera mount bracket, for instance.

Global change

Activate this function if the global change, as set with the Global change slide control, should trigger an alarm.

Scene too bright

Activate this function if tampering associated with exposure to extreme light (for instance, shining a flashlight directly on the objective) should trigger an alarm. The average brightness of the scene provides a basis for recognition.

Scene too dark

Activate this function if tampering associated with covering the lens (for instance, by spraying paint on it) should trigger an alarm. The average brightness of the scene provides a basis for recognition.

Scene too noisy

Activate this function if tampering associated with EMC interference (noisy scene as the result of a strong interference signal in the vicinity of the video lines), as an example, should trigger an alarm.

Reference check

You can save a reference image that is continuously compared with the current video image. If the current video image in the marked areas differs from the reference image, an alarm is triggered. This allows you to detect tampering that would otherwise not be detected, for example if the camera is turned.

1.Click Reference to save the currently visible video image as a reference.

2.Click Select Area and select the areas in the reference image that are to be monitored.

3.Check the box Reference check to activate on-going matching. The stored reference image is displayed in black and white below the current video image, and the selected areas are marked in yellow.

4.Select the Disappearing edges or Appearing edges option to specify the reference check once again.

Select Area

You can select the image areas in the reference image that are to be monitored. The video image is subdivided into 858 square fields. Each of these fields can be activated or deactivated individually.

NOTICE!

i Select only those areas for reference monitoring in which no movement takes place and that are always evenly lit, as false alarms could otherwise be triggered.

1.Click Select Area to configure the sensor fields. A new window will open.

2.If necessary, click Clear All first to clear the current selection (fields marked yellow).

3.Left-click the fields to be activated. Activated fields are marked yellow.

4.If necessary, click Select All to select the entire video frame for monitoring.

5.Right-click any fields you wish to deactivate.

Bosch Security Systems

Installation and Operating Manual

DOC V4.0 2009.06

Page 63
Image 63
Bosch Appliances VIP X1600 M4S manual Scene too bright, Scene too dark, Scene too noisy, Reference check, Select Area