Bosch Appliances VIP X1600 M4S manual Preview for, Profile name, Target data rate

Models: VIP X1600 M4S

1 124
Download 124 pages 32.66 Kb
Page 45
Image 45

VIP X1600 M4S

Configuration Using a Web Browser en 45

 

 

High resolution (4CIF/D1)

High resolution for high bandwidth connections, resolution 704 × 576/480 pixels

DSL

For DSL connections with 500 kbps, resolution 352 × 288/240 pixels

ISDN (2B)

For ISDN connections via two B-channels, resolution 352 × 288/240 pixels

ISDN (1B)

For ISDN connections via one B-channel, resolution 352 × 288/240 pixels

Modem

For analog modem connections with 20 kbps, resolution 352 × 288/240 pixels

GSM

For GSM connections at 9,600 baud, resolution 176 × 144/120 pixels

You can choose between the code algorithms MPEG-4 SH++ and H.264 for each data stream. H.264 requires a lower bandwidth at the same video quality but it does not offer 4CIF resolution. 4CIF resolution is only possible with MPEG-4 SH++.

1.Select the required profile for every data stream.

2.Select the required code algorithm for every data stream.

You can change individual parameter values of a profile and you can also change the name. You can switch between profiles by clicking the appropriate tabs.

CAUTION!

The profiles are rather complex. They include a large number of parameters that interact with

!one another, so it is generally best to use the default profiles.

Change the profiles only once you are fully familiar with all the configuration options. In the default setting, Stream 2 is transmitted for alarm connections and automatic connections. Bear this fact in mind when assigning the profile.

NOTICE!

i

All parameters combine to make up a profile and are dependent on one another. If you enter a

 

 

setting that is outside the permitted range for a particular parameter, the nearest permitted

 

value will be substituted when the settings are saved.

 

 

Preview for

Select which video data stream should be displayed in the previews. You can deactivate the display of the video images if the performance of the computer is affected too strongly by the decoding of the data streams.

1.Check the box for the required data stream.

2.Click the i icon above the relevant preview to display further information about the data stream.

Profile name

You can enter a new name for the profile here. The name is then displayed in the list of available profiles in the Active profile field.

Target data rate

You can limit the data rate for the module to optimize utilization of the bandwidth in your network. The target data rate should be set according to the desired picture quality for typical scenes with no excessive motion.

For complex images or frequent changes of image content due to frequent movements, this limit can be temporarily exceeded up to the value you enter in the Maximum data rate field.

Bosch Security Systems

Installation and Operating Manual

DOC V4.0 2009.06

Page 45
Image 45
Bosch Appliances VIP X1600 M4S manual Preview for, Profile name, Target data rate