VIP X1600 M4S | Configuration Using a Web Browser en 77 |
|
|
Force registration now
You can force the registration by transferring the IP address to the DynDNS server. Entries that change frequently are not provided in the Domain Name System. It is a good idea to force the registration when you are setting up the device for the first time. Only use this function when necessary and no more than once a day, to avoid the possibility of being blocked by the service provider. To transfer the IP address of the module, click the Register button.
Status
The status of the DynDNS function is displayed here for information purposes. You cannot change any of these settings.
5.38 | Advanced Mode: Advanced |
The settings on this page are used to implement advanced settings for the network.
Some changes only take effect after the unit is rebooted. In this case, the Set button changes to Set and Reboot.
1.Make the desired changes.
2.Click the Set and Reboot button. The module is rebooted and the changed settings are activated.
SNMP
The module supports the SNMP V2 (Simple Network Management Protocol) for managing and monitoring network components, and can send SNMP messages (traps) to IP addresses. The unit supports SNMP MIB II in the unified code. If you wish to send SNMP traps, enter the IP addresses of one or two required target devices here.
If you select On for the SNMP parameter and do not enter an SNMP host address, the module does not send them automatically, but only replies to SNMP requests. If you enter one or two
Bosch Security Systems | Installation and Operating Manual | DOC V4.0 2009.06 |