option can be useful if the connection to the central unit is lost. Once activation is complete, you must enter the required IP address.
IGMP source IP
Enter the IP address that you want to use here. The IP address that you use should be as high as possible and at least higher than that of the standard IGMP querier.
5.40 | Advanced Mode: Multicasting |
In addition to a 1:1 connection between an encoder and a single receiver (unicast), the module can enable multiple receivers to receive the video signal from an encoder simultaneously. The device either duplicates the data stream itself and then distributes it to multiple receivers
NOTICE!
i | Multicast operation requires a |
| |
| Group Management IGMP protocols. Other group management protocols are not supported. |
| The TCP protocol does not support multicast connections. |
|
|
A special IP address (class D address) must be configured for multicast operation in a
The network must support group IP addresses and the Internet Group Management Protocol (IGMP V2). The address range is from 225.0.0.0 to 239.255.255.255.
The multicast address can be the same for multiple streams. However, it will be necessary to use a different port in each case so that multiple data streams are not sent simultaneously using the same port and multicast address.
NOTICE!
i You must set the parameters for each encoder (video input) and for each stream individually. The numbering follows the labeling of the video inputs on the actual unit.