Installation/Operation Supplement
Gap Setting for Vibration Switch (Variable-Speed and Fixed-Speed Models)
| 18, 20 | 27, 30 | 35 | 40 | 50 | 60 | 80 | 125 |
|
|
|
|
|
|
|
|
|
Switch gap | 0.015- | 0.025- | 0.030- | 0.020- | 0.025- | 0.013- | 0.009- | 0.006- |
setting* | 0.025 in. | 0.035 in. | 0.040 in. | 0.030 in. | 0.035 in. | 0.015 in. | 0.011 in. | 0.008 in. |
| (0.38- | (0.64- | (0.76- | (0.51- | (0.64- | (0.20- | (0.23- | (0.15- |
| 0.64 mm) | 0.89 mm) | 1.02 mm) | 0.64 mm) | 0.89 mm) | 0.25 mm) | 0.28 mm) | 0.20 mm) |
|
|
|
|
|
|
|
|
|
* Gap setting should be made with
After the machine has been properly installed, the vibration switch gap must be measured before conducting the Control Function Test. Locate the gap found between the vibration switch and the machine structure. Refer to Figures 1, 2, 3, 4 and 5. To check the gap setting of the switch, proceed as follows:
1.Remove the front panel on
2.Measure the gap distance when the switch is in both the open and closed positions. The specifications should be at the minimum switch gap setting when the switch is open and at the maximum switch gap setting when the switch is closed. If these distances are not correct, adjust the balance switch to these specifications.
NOTE: The standard position of the switch is open, or3.Tighten nuts on switch extension after adjusting the gap. Measure the gap distance to verify accurate setting.
8 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | F232145 (EN) |