Installation/Operation Supplement

Electrical Specifications

60 Pound Capacity Models

 

Voltage Designation

 

 

Standard

 

 

Electric Heat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Code

Voltage

Cycle

Phase

Wire

LoadFull Amps

Circuit Breaker

AWG

2

LoadFull Amps

Circuit Breaker

AWG

2

 

 

 

 

 

 

 

 

mm

 

 

 

mm

 

 

 

 

 

2 Speed Models

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

380-415

50

3

4

4

15

14

2.5

37

50

8

10.0

 

 

 

 

 

 

 

 

 

 

 

 

 

D

220-240

50

3

3

7

20

12

4.0

64

70

4

25.0

 

 

 

 

 

 

 

 

 

 

 

 

 

F

440-480

60

3

3

4

15

14

2.5

41

50

8

10.0

 

 

 

 

 

 

 

 

 

 

 

 

 

H

380

60

3

3

3

20

12

4.0

33

50

8

10.0

 

 

 

 

 

 

 

 

 

 

 

 

 

J

200

50

3

3

8

20

12

4.0

55

60

6

16.0

 

 

 

 

 

 

 

 

 

 

 

 

 

O

208-240

60

3

3

7

20

12

4.0

64

70

4

25.0

 

 

 

 

 

 

 

 

 

 

 

 

 

X

200-240

50/60

1/3

2/3

9

20

12

4.0

N/A

N/A

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Variable-Speed Models

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

440-480

50/60

3

3

4

15

14

2.5

42

50

8

10.0

 

 

 

 

 

 

 

 

 

 

 

 

 

P

380-415

50/60

3

3

5

15

14

2.5

37

40

8

10.0

 

 

 

 

 

 

 

 

 

 

 

 

 

Q

200-240

50/60

3

3

6

15

14

2.5

65

60

6

16.0

 

 

 

 

 

 

 

 

 

 

 

 

 

X

200-240

50/60

1/3

2/3

10

20

12

4.0

N/A

N/A

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: Wire sizes shown are for copper, THHN, 90° conductor per NEC article 310.

Table 12

F232145 (EN)

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

23