Installation/Operation Supplement

Table 3 (Continued)

Drive Train Information

Number of motors in drive train

1

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

Drive motor power, HP (kW)

2

2

2

2

2

3

5

7.5

 

 

 

(1.5)

(1.5)

(1.5)

(1.5)

(1.5)

(2.2)

(3.7)

(5.6)

 

 

 

 

 

 

 

 

 

 

Cylinder Speeds

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gentle wash/reverse speed, RPM

29

27

26

26

24

24

22

27

 

 

 

 

 

 

 

 

 

 

Wash/reverse speed, RPM

52

48

46

47

43

43

40

37

 

 

 

 

 

 

 

 

 

 

Distribution speed, RPM

82

86

73

73

68

77

63

62

 

 

 

 

 

 

 

 

 

 

Low extract speed, RPM

366

343

328

328

307

307

280

260

 

 

 

 

 

 

 

 

 

 

Medium extract speed, RPM

534

500

478

478

447

447

408

380

(Not available on Electronic Control models.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High extract speed, RPM

685

641

613

614

573

574

524

485

 

 

 

 

 

 

 

 

 

 

Centrifugal Force Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gentle wash centrifugal force, Gs

0.25

0.25

0.25

0.25

0.25

0.25

0.25

0.43

 

 

 

 

 

 

 

 

 

 

Wash/reverse centrifugal force, Gs

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

 

 

 

 

 

 

 

 

 

 

Distribution centrifugal force, Gs

2

2

2

2

2

2

2

2

 

 

 

 

 

 

 

 

 

 

Low extract centrifugal force, Gs

40

40

40

40

40

40

40

40

 

 

 

 

 

 

 

 

 

 

Medium extract centrifugal force, Gs

85

85

85

85

85

85

85

85

 

 

 

 

 

 

 

 

 

 

High extract centrifugal force, Gs

140

140

140

140

140

140

140

140

 

 

 

 

 

 

 

 

 

 

Balance Detection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vibration switch installed*

Standard

Standard

Standard

Standard

Standard

Standard

Standard

Standard

 

 

 

 

 

 

 

 

 

 

Direct Steam Heating (Optional)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Steam inlet connection size,

1/2

1/2

1/2

1/2

1/2

1/2

1/2

3/4

in. (mm)

(13)

(13)

(13)

(13)

(13)

(13)

(13)

(19)

 

 

 

 

 

 

 

 

 

 

Number of steam inlets

1

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

Steam required to raise bath water

LOW

0.62

0.92

2.1

2.09

2.8

3.6

4.1

6.8

temperature 10°F (6°C), lbs. (kg)

 

(0.28)

(0.42)

(1.51)

(1.51)

(2.0)

(1.63)

(2.93)

(4.9)

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH

0.88

1.31

2.69

2.84

3.6

5.5

6.0

8.9

 

 

 

(0.4)

(0.6)

(1.96)

(2.04)

(2.59)

(2.49)

(4.34)

(6.4)

 

 

 

 

 

 

 

 

 

 

 

Average steam use per cycle, bhp (kg)

0.54

0.73

1.4

1.43

1.8

2.32

2.93

4.5

 

 

 

(8.3)

(11.3)

(21.6)

(22.4)

(28.9)

(36.4)

(45.9)

(71)

 

 

 

 

 

 

 

 

 

 

Electrical Heating (Optional)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total electrical heating capacity, kW

7.8

7.8

15.6

15.6

23.4

23.4

31.2

N/A

 

 

 

 

 

 

 

 

 

Electrical heating elements

3

3

6

3

9

9

12

N/A

 

 

 

 

 

 

 

 

 

Electrical heat element size, kW

2.6

2.6

2.6

5.2

2.6

2.6

2.6

N/A

 

 

 

 

 

 

 

 

 

 

 

* Refer to Gap Setting for Vibration Switch (Variable-Speed and Fixed-Speed Models) section for specifications.

10

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F232145 (EN)