Installation/Operation Supplement
Table 3 (Continued)
Drive Train Information
Number of motors in drive train | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | ||
|
|
|
|
|
|
|
|
|
| |
Drive motor power, HP (kW) | 2 | 2 | 2 | 2 | 2 | 3 | 5 | 7.5 | ||
|
|
| (1.5) | (1.5) | (1.5) | (1.5) | (1.5) | (2.2) | (3.7) | (5.6) |
|
|
|
|
|
|
|
|
|
| |
Cylinder Speeds |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |
Gentle wash/reverse speed, RPM | 29 | 27 | 26 | 26 | 24 | 24 | 22 | 27 | ||
|
|
|
|
|
|
|
|
|
| |
Wash/reverse speed, RPM | 52 | 48 | 46 | 47 | 43 | 43 | 40 | 37 | ||
|
|
|
|
|
|
|
|
|
| |
Distribution speed, RPM | 82 | 86 | 73 | 73 | 68 | 77 | 63 | 62 | ||
|
|
|
|
|
|
|
|
|
| |
Low extract speed, RPM | 366 | 343 | 328 | 328 | 307 | 307 | 280 | 260 | ||
|
|
|
|
|
|
|
|
|
| |
Medium extract speed, RPM | 534 | 500 | 478 | 478 | 447 | 447 | 408 | 380 | ||
(Not available on Electronic Control models.) |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |
High extract speed, RPM | 685 | 641 | 613 | 614 | 573 | 574 | 524 | 485 | ||
|
|
|
|
|
|
|
|
|
| |
Centrifugal Force Data |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |
Gentle wash centrifugal force, Gs | 0.25 | 0.25 | 0.25 | 0.25 | 0.25 | 0.25 | 0.25 | 0.43 | ||
|
|
|
|
|
|
|
|
|
| |
Wash/reverse centrifugal force, Gs | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | ||
|
|
|
|
|
|
|
|
|
| |
Distribution centrifugal force, Gs | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | ||
|
|
|
|
|
|
|
|
|
| |
Low extract centrifugal force, Gs | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | ||
|
|
|
|
|
|
|
|
|
| |
Medium extract centrifugal force, Gs | 85 | 85 | 85 | 85 | 85 | 85 | 85 | 85 | ||
|
|
|
|
|
|
|
|
|
| |
High extract centrifugal force, Gs | 140 | 140 | 140 | 140 | 140 | 140 | 140 | 140 | ||
|
|
|
|
|
|
|
|
|
| |
Balance Detection |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |
Vibration switch installed* | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | ||
|
|
|
|
|
|
|
|
|
| |
Direct Steam Heating (Optional) |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |
Steam inlet connection size, | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 3/4 | ||
in. (mm) | (13) | (13) | (13) | (13) | (13) | (13) | (13) | (19) | ||
|
|
|
|
|
|
|
|
|
| |
Number of steam inlets | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | ||
|
|
|
|
|
|
|
|
|
| |
Steam required to raise bath water | LOW | 0.62 | 0.92 | 2.1 | 2.09 | 2.8 | 3.6 | 4.1 | 6.8 | |
temperature 10°F (6°C), lbs. (kg) |
| (0.28) | (0.42) | (1.51) | (1.51) | (2.0) | (1.63) | (2.93) | (4.9) | |
|
|
|
|
|
|
|
|
|
|
|
|
| HIGH | 0.88 | 1.31 | 2.69 | 2.84 | 3.6 | 5.5 | 6.0 | 8.9 |
|
|
| (0.4) | (0.6) | (1.96) | (2.04) | (2.59) | (2.49) | (4.34) | (6.4) |
|
|
|
|
|
|
|
|
|
|
|
Average steam use per cycle, bhp (kg) | 0.54 | 0.73 | 1.4 | 1.43 | 1.8 | 2.32 | 2.93 | 4.5 | ||
|
|
| (8.3) | (11.3) | (21.6) | (22.4) | (28.9) | (36.4) | (45.9) | (71) |
|
|
|
|
|
|
|
|
|
| |
Electrical Heating (Optional) |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |
Total electrical heating capacity, kW | 7.8 | 7.8 | 15.6 | 15.6 | 23.4 | 23.4 | 31.2 | N/A | ||
|
|
|
|
|
|
|
|
| ||
Electrical heating elements | 3 | 3 | 6 | 3 | 9 | 9 | 12 | N/A | ||
|
|
|
|
|
|
|
|
| ||
Electrical heat element size, kW | 2.6 | 2.6 | 2.6 | 5.2 | 2.6 | 2.6 | 2.6 | N/A | ||
|
|
|
|
|
|
|
|
|
|
|
* Refer to Gap Setting for Vibration Switch
10 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | F232145 (EN) |