Installing the Unit . . .

Step 1:

Position Unit Near Installation Area

Move unit so that it is within four feet of the desired area of installation.

CAUTION

Washer and dryer are not designed to be operated as separated, side-by-side units.

W187

H243I

Step 2:

Connect Water Inlet Hoses

NOTE: Refer to Section on Water Supply Requirements before connecting water inlet hoses.

Remove the four plain rubber washers from accessories bag, and install them according to the illustration.

Turn on the water supply faucets and flush the lines for approximately two minutes to remove any foreign materials that could clog the screens in the water mixing valve.

NOTE: When installing in newly constructed or renovated building, it is very important to flush the lines since build-up may have occurred during construction.

IMPORTANT: Thread hose couplings onto valve connections finger-tight, then approximately 1/4 turn with pliers. DO NOT cross thread or overtighten couplings.

Turn water on and check for leaks. If leaks are found, retighten the hose couplings. Continue tightening and rechecking until no leaks are found.

RUBBER WASHER

(Plain)

RUBBER WASHER

(Plain)

INLET

HOSE

INSTALL THIS

 

END OF HOSE

INSTALL THIS END OF HOSE

TO WATER

TO VALVE CONNECTIONS

SUPPLY FAUCET

AT REAR OF WASHER

 

 

H091IE1A

 

COLD WATER

 

CONNECTION

WATER

 

SUPPLY

 

FAUCETS

HOT WATER

 

 

CONNECTION

WATER

MIXING VALVE

WATER

 

INLET

H096IE1A

HOSES

 

504509

9