Installing the Unit . . .
Step 1:
Position Unit Near Installation Area
Move unit so that it is within four feet of the desired area of installation.
CAUTION
Washer and dryer are not designed to be operated as separated,
W187
H243I
Step 2:
Connect Water Inlet Hoses
NOTE: Refer to Section on Water Supply Requirements before connecting water inlet hoses.
Remove the four plain rubber washers from accessories bag, and install them according to the illustration.
Turn on the water supply faucets and flush the lines for approximately two minutes to remove any foreign materials that could clog the screens in the water mixing valve.
NOTE: When installing in newly constructed or renovated building, it is very important to flush the lines since
IMPORTANT: Thread hose couplings onto valve connections
Turn water on and check for leaks. If leaks are found, retighten the hose couplings. Continue tightening and rechecking until no leaks are found.
RUBBER WASHER
(Plain)
RUBBER WASHER
(Plain)
INLET
HOSE
INSTALL THIS |
| |
END OF HOSE | INSTALL THIS END OF HOSE | |
TO WATER | ||
TO VALVE CONNECTIONS | ||
SUPPLY FAUCET | ||
AT REAR OF WASHER | ||
| ||
| H091IE1A | |
| COLD WATER | |
| CONNECTION | |
WATER |
| |
SUPPLY |
| |
FAUCETS | HOT WATER | |
| ||
| CONNECTION |
WATER
MIXING VALVE
WATER |
|
INLET | H096IE1A |
HOSES |
|
504509 | 9 |