WEATHER HOOD

OR SWEEP ELBOW (No cap or screen)

PARAPET

MAIN COLLECTOR DUCT

WALL

MAIN COLLECTOR DUCT

180˚ SWEEP

ELBOW (No cap or screen)

24" MIN.

(60.96 cm)

ROOF

D039IE3A

Main collector duct should be sized according to specifications shown below.

Number

Minimum Diameter of

Minimum Diameter of

of Dryers

Horizontal Collector Duct

Vertical Collector Duct

 

 

 

2

7 inch (17.8 cm)

8 inch (20.3 cm)

 

 

 

3

8 inch (20.3 cm)

9 inch (22.9 cm)

 

 

 

4

9 inch (22.9 cm)

10 inch (25.4 cm)

 

 

 

5

10 inch (25.4 cm)

11 inch (27.9 cm)

 

 

 

6

11 inch (27.9 cm)

12 inch (30.5 cm)

 

 

 

7

12 inch (30.5 cm)

13 inch (32.6 cm)

 

 

 

8

12 inch (30.5 cm)

14 inch (35.6 cm)

 

 

 

9

13 inch (32.6 cm)

15 inch (38.1 cm)

 

 

 

10

14 inch (35.6 cm)

15 inch (38.1 cm)

 

 

 

11

14 inch (35.6 cm)

16 inch (40.6 cm)

 

 

 

NOTE: Main collector duct should be equipped with an auxiliary fan that can maintain the duct airflow at a minimum of 1200 feet (366 m) per minute. If you do not have a fan, clean the main collector duct at least twice a year.

34

504509