Location Requirements . . .

Select a location with a solid floor.

The unit must not be installed or stored in an area where it will be exposed to water and/or weather.

Leveling legs can be adjusted from inside the unit with a 9/16" deep well socket. All four legs must rest firmly on the floor so the weight of the unit is evenly distributed.

The unit must not rock and must be level from side-to- side and front-to-back.

IMPORTANT: Unless completely assembled, DO NOT slide the unit across the floor. DO NOT slide the unit more than four feet once the leveling legs have been extended, as the legs and the base could become damaged.

The unit needs sufficient clearance and an adequate air supply for proper operation and ventilation, and for easier installation and servicing. (Minimum clearances are shown below.)

Dryer And Exhaust Duct Clearances

Area

Description

Minimum Clearance

 

 

 

A

Left Dryer Side

0" (0 cm)

 

 

 

B

Right Dryer Side

1" (2.54 cm)

 

 

 

C

Dryer Top

6" (15.24 cm)

 

 

 

D

Dryer Rear

2" (5.1 cm)

 

 

 

E

Exhaust Duct Clearance to Combustible Materials

2" (5.1 cm)

 

 

 

NOTE: Shaded areas indicate adjacent structure.

C

D

E

E

 

 

 

 

 

 

 

 

A

 

B

 

 

H245IE1A

 

 

 

 

 

 

28

504509