Installing the Unit
Step 1: Position Unit Near Installation Area
Move unit so that it is within 4 ft. of the desired area of installation.
CAUTION
Washer and dryer are not designed to be operated as separated,
W187
SWD443N
SWD443N
Figure 3
Step 2: Connect Water Inlet Hoses
NOTE: Refer to section on Water Supply Requirements before connecting water inlet hoses.
Remove the four plain rubber washers from accessories bag, and install them according to Figure 4.
Turn on the water supply faucets and flush the lines for approximately two minutes to remove any foreign materials that could clog the screens in the water mixing valve.
Installation
NOTE: When installing in newly constructed or renovated building, it is very important to flush the lines since
IMPORTANT: Thread hose couplings onto valve connections
1/4 turn with pliers. DO NOT cross thread or overtighten couplings.
Turn water on and check for leaks. If leaks are found, retighten the hose couplings. Continue tightening and rechecking until no leaks are found.
1
2
H091I
H091I
1Rubber Washer (Plain)
2Inlet Hose
Figure 4
2 1
WATER MIXING
VALVE
4 | 3 |
| |
| SWD548N |
SWD548N
1Water Supply Faucets
2Cold Water Connection
3Hot Water Connection
4Water Inlet Hoses
Figure 5
800937 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 9 |