Installation

13

 

2

120 ± 12

0

V.A.C.

V.A.C.

5

120 + 12

V.A.C.

4

STANDARD 120 VOLT, 60 HERTZ, 3-WIRE

EFFECTIVELY GROUNDED CIRCUIT

D799I

1L1

2Ground

3Neutral Side

4Round Grounding Prong

5Neutral

Figure 25

DO NOT OPERATE OTHER APPLIANCES ON THE SAME CIRCUIT. DO NOT OVERLOAD CIRCUITS!

Do not operate both a washer and gas dryer on the same circuit. Use separately fused 15 Amp circuits.

WARNING

To reduce the risk of electric shock or fire, DO NOT use an extension cord or an adapter to connect the washer to the electrical power source.

W031

Electric Dryer

(120/240 Volt, 60 Hertz, 3-Wire Installation)

(120/208 Volt, 60 Hertz, 3-Wire Installation)*

*Alternative Heating Element Required

NOTE: The wiring diagram is located behind the control panel, inside the control cabinet.

WARNING

To reduce the risk of fire, electric shock or personal injury, all wiring and grounding MUST conform with the latest edition of the National Electrical Code ANSI/NFPA 70 or the Canadian Electrical Code, CSA C22.1, and such local regulations as might apply. It is the customer’s responsibility to have the wiring and fuses checked by a qualified electrician to make sure the laundry room has adequate electrical power to operate the dryer.

W035

20

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

800937