Installation

Step 4: (Gas Dryer Only) Connect Gas Supply Pipe

For further assistance, refer to section on Gas Requirements.

1.Make certain dryer is equipped for use with the type of gas in laundry room. Dryer is equipped at the factory for Natural Gas with a 3/8 in. N.P.T. gas connection.

2.Remove the shipping cap from the gas connection at the rear of the dryer. Make sure you do not damage the pipe threads when removing the cap.

3.Connect to gas supply pipe using a new flexible stainless steel connector.

4.Tighten all connections securely. Turn on gas and check all pipe connections (internal and external) for gas leaks with a non-corrosive leak detection fluid.

5.For L.P. (Liquefied Petroleum) gas connection, refer to section on Gas Requirements.

1

2

5

 

4

3

D434I

1

New Stainless Steel Flexible Connector –

4

Black Iron Pipe

 

Use only if allowed by local codes

 

Shorter than 20' (6.1 m) – Use 3/8" pipe

 

(Use Design A.G.A. Certified Connector)

 

Longer than 20' (6.1 m) – Use 1/2" pipe

2

1/8" N.P.T. Pipe Plug

5

3/8" N.P.T. Gas Connection

 

(For checking inlet gas pressure)

 

 

3Equipment Shut-Off Valve – Installed within 6' (1.8 m) of dryer

Figure 11

12

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

800937