Installation

2.Remove the three screws holding the three wires to the terminal block terminals. Save these screws. Loosen the strain relief screw and pull the cord or wires out through the rear of the dryer.

D696I

Figure 32

3.Remove ground screw and save for use in step 5. Remove wire and use in step 6.

1

D697I

1Ground Screw

Figure 33

4.Use a strain relief and insert end of power cord through power supply hole.

1

D698I

1Power Cord Ground Wire

Figure 34

5.Attach power cord ground (green) wire to rear bulkhead using ground screw removed in step 3.

6.Use the three screws from the envelope located in the cylinder to attach the remaining power cord wires to the terminal block as follows:

a.Red wire to “L1” terminal.

b.Black wire to “L2” terminal.

c.White wire to Neutral terminal.

1

2

7

6

3

5

4

DRY522N

1“L1” Terminal

2White

3“L2” Terminal

4Black

5Green

6Red

7Neutral Terminal

Figure 35

NOTE: When installing the white wire, loop the free eyelet end of the ground wire (removed in step 3) and attach along with the white wire to the neutral (center) terminal on the terminal block.

7. Tighten all screws firmly.

IMPORTANT: Failure to tighten these screws firmly may result in wire failure at the terminal block.

8.Check the continuity of the ground connection before plugging the cord into the outlet. Use an acceptable indicating device connected to the center grounding pin of the plug and the green screw on the back of cabinet.

9.Reinstall access cover and screw.

24

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

800937