Step 6: (Washer Only) Remove the Shock Sleeves and Shipping Brace
Remove front access panel by removing the two screws.
Remove bolts and lockwashers from shipping brace with a wrench and remove brace. Remove shock sleeves by pulling on the yellow rope.
Remove label from front side of front access panel and place on backside of front access panel.
NOTE: The shipping brace, bolts, lockwashers and shock sleeves should be saved and MUST be reinstalled whenever the unit is moved more than four feet. Do not lift or transport unit from front or without shipping materials installed.
Store the shipping materials in the bag provided in the accessories bag. Save materials for use whenever the unit is moved.
NOTE: The shipping materials MUST be reinstalled whenever the unit is moved. Refer to Moving Unit to a New Location section for proper instructions on reinstalling the shipping materials.
Reinstall front access panel.
IMPORTANT: DO NOT tip unit more than
152.4mm (6 inches) in any direction after shipping brace has been removed. Shock absorbers may separate and damage to unit may result. For leveling purposes, the unit may be tilted a maximum of 152.4 mm (6 inches) in any direction.
Installation
1
4
2
3
H336I
1Shock Sleeves
2Motor Mount
3Bolts and Lockwashers
4Hooked End of Shipping Brace
Figure 10
802031 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 17 |