Installation
Exhaust System
IMPORTANT: Keep exhaust duct as short as possible.
NOTE: Be certain old ducts are cleaned before installing your new unit.
For best drying results, recommended maximum length of exhaust system is shown in Table 1.
To prevent backdraft when unit is not in operation, outer end of exhaust pipe must have a weather hood with hinged dampers (obtain locally).
NOTE: Weather hood should be installed at least 305 mm (12 inches) above the ground. Larger clearances may be necessary in areas where heavy snowfall can occur.
Number of |
| Weather Hood Type |
90° Elbows | Recommended | Use Only for Short Run Installations |
| 102 mm |
|
| 102 mm |
|
|
|
| ||
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
| ||||
|
|
| 64 mm | |||||||
|
|
| (4 in.) | |||||||
| (4 in.) |
|
|
|
| |||||
|
|
| D802I |
| ||||||
|
|
| D673I |
|
|
| ||||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Maximum length of 102 mm (4 in.) diameter rigid metal duct | |||||||||
|
|
|
|
|
|
|
|
|
|
|
0 |
| 19.8 m (65 ft.) | 16.8 m (55 ft.) | |||||||
|
|
|
|
|
|
|
|
|
|
|
1 |
| 16.8 m (55 ft.) | 14.3 m (47 ft.) | |||||||
|
|
|
|
|
|
|
|
|
|
|
2 |
| 14.3 m (47 ft.) | 12.5 m (41 ft.) | |||||||
|
|
|
|
|
|
|
|
|
|
|
3 |
| 11.0 m (36 ft.) | 9.1 m (30 ft.) | |||||||
|
|
|
|
|
|
|
|
|
|
|
4 |
| 8.5 m (28 ft.) | 6.7 m (22 ft.) | |||||||
|
|
|
|
|
|
|
|
|
| |
| Maximum length of 102 mm (4 in.) diameter flexible metal duct | |||||||||
|
|
|
|
|
|
|
|
|
|
|
0 |
| 13.7 m (45 ft.) | 10.7 m (35 ft.) | |||||||
|
|
|
|
|
|
|
|
|
|
|
1 |
| 10.7 m (35 ft.) | 8.2 m (27 ft.) | |||||||
|
|
|
|
|
|
|
|
|
|
|
2 |
| 9.1 m (30 ft.) | 6.4 m (21 ft.) | |||||||
|
|
|
|
|
|
|
|
|
|
|
3 |
| 7.6 m (25 ft.) | 5.2 m (17 ft.) | |||||||
|
|
|
|
|
|
|
|
|
|
|
4 |
| 6.1 m (20 ft.) | 4.5 m (15 ft.) | |||||||
|
|
|
|
|
|
|
|
|
|
|
NOTE: Deduct 1.8 m (6 ft.) for each additional elbow.