Installation
IMPORTANT: Use only a U.L. listed No. 10 (copper wire only) two conductor power supply cord kit rated 230 Volts (minimum) 30 Amperes for electric dryers, and labeled as suitable for use in a clothes dryer.
4. Tighten these
IMPORTANT: Failure to tighten these screws firmly may result in wire failure at the terminal block.
5.Secure the strain relief to the power cord, or wires, where they enter the dryer cabinet.
6.Reinstall access cover and screw.
1
4
WARNING
Dryer is shown with the access cover removed for illustration purposes only. To reduce the risk of an electric shock, serious injury or death, NEVER operate the dryer with the access cover removed.
W157
WARNING
To reduce the risk of electric shock, serious injury or death, earth (ground) the dryer frame externally by connecting one end of a grounding wire under ground screw on cabinet rear (see above) and the other end to a known effective ground.
12
11
2
3
W156
2
10
4
|
| WIRE |
9 |
| CONNECTION |
| DETAIL | |
| 7 |
|
8 | 6 | 5 |
|
|
D703I
1Earth (Ground) Wire (Green/Yellow)
2“L” Terminal
3Terminal Block
4Hex Head Screws (Slotted)
5Power Cord Wiring
6Direct Wiring
7Strain Relief (Not supplied with dryer)
8Power Cord or Direct Wire (Not supplied with dryer)
9Access Cover
10Earth (Ground) Wire
11Earth (Ground) Screw
12“N” Terminal
Figure 19
1
4
3
D821I
130 Amp Fuse
2230 Volt Supply
3Terminal Block in Dryer
4Rear Bulkhead
Figure 20
WARNING
To reduce the risk of fire, electric shock, serious injury or death, all wiring and grounding MUST conform with the latest edition of the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1, and such local regulations as might apply. It is the customer’s responsibility to have the wiring and fuses installed by a qualified electrician to make sure adequate electrical power is available to the dryer.
W512