Installation

IMPORTANT: Use only a U.L. listed No. 10 (copper wire only) two conductor power supply cord kit rated 230 Volts (minimum) 30 Amperes for electric dryers, and labeled as suitable for use in a clothes dryer.

4. Tighten these wire-binding screws firmly.

IMPORTANT: Failure to tighten these screws firmly may result in wire failure at the terminal block.

5.Secure the strain relief to the power cord, or wires, where they enter the dryer cabinet.

6.Reinstall access cover and screw.

1

4

WARNING

Dryer is shown with the access cover removed for illustration purposes only. To reduce the risk of an electric shock, serious injury or death, NEVER operate the dryer with the access cover removed.

W157

WARNING

To reduce the risk of electric shock, serious injury or death, earth (ground) the dryer frame externally by connecting one end of a grounding wire under ground screw on cabinet rear (see above) and the other end to a known effective ground.

12

11

2

3

W156

2

10

4

 

 

WIRE

9

 

CONNECTION

 

DETAIL

 

7

 

8

6

5

 

 

D703I

1Earth (Ground) Wire (Green/Yellow)

2“L” Terminal

3Terminal Block

4Hex Head Screws (Slotted)

5Power Cord Wiring

6Direct Wiring

7Strain Relief (Not supplied with dryer)

8Power Cord or Direct Wire (Not supplied with dryer)

9Access Cover

10Earth (Ground) Wire

11Earth (Ground) Screw

12“N” Terminal

Figure 19

1

4

3

D821I

130 Amp Fuse

2230 Volt Supply

3Terminal Block in Dryer

4Rear Bulkhead

Figure 20

WARNING

To reduce the risk of fire, electric shock, serious injury or death, all wiring and grounding MUST conform with the latest edition of the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1, and such local regulations as might apply. It is the customer’s responsibility to have the wiring and fuses installed by a qualified electrician to make sure adequate electrical power is available to the dryer.

W512

22