Earthing Instructions

The washer must be earthed. In the event of malfunction or breakdown, earthing will reduce the risk of electric shock by providing a path of least resistance for electric current. The washer must be properly earthed in accordance with all local codes and ordinances.

If the laundry room’s electrical supply does not meet the above specifications and/or if you are not sure the laundry room has an effective earth, have a qualified electrician or your local electrical utility company check it and correct any problems.

WARNING

Improper connection of the equipment- earthing conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the washer is properly earthed.

W032

Installation

Dryer

230 Volt, 60 Hertz, 2 Wire

Plus Grounded (Earth) Wire Installation

WARNING

To reduce the risk of fire, electric shock, serious injury or death, the electrical installation should conform to the National Electrical Code, ANSI/NFPA 70, and such local regulations as might apply.

W155

NOTE: The wiring diagram is located inside the control hood.

This dryer is designed to be operated on a two-wire plus grounded (earth) wire, 230 Volt, 60 Hertz, single- phase supply circuit. It is designed to be fused at

30 Amperes. Consult nameplate for model and electrical ratings.

NOTE: Branch circuit wire size requirements to laundry room dryer outlet.

Wire Length

Electric Dryer

 

 

Less than 4.5 m

10 A.W.G. Copper Wire Only

(15 ft.)

 

 

 

Longer than 4.5 m

8 A.W.G. Copper Wire Only

(15 ft.)

 

 

 

Use U.L. (Underwriters Laboratories) listed wire. Allow sufficient slack in wiring so dryer can be moved from its normal location when necessary.

1.Remove the screw and terminal block access cover from the rear of dryer cabinet.

2.Insert ends of direct wire through power supply hole (containing proper strain relief) in rear of dryer cabinet. Connect the power cord, or direct wiring, to the two outer terminal block terminals using the two wire-binding (10 - 32 x 3/8 inch) screws from the accessories pack in the envelope shipped inside the dryer cylinder.

3.Attach ground (earth) wire to rear bulkhead as shown.

802031