Installation

5

1

A B C D E F G H I J K

2

3

30°

1

2

AIR

FLOW

4

EXHAUST AIR FLOW

MAXIMUM LENGTH OF DUCT

9.1 m (30 feet)

 

 

 

EXHAUST

HORIZONTAL EXHAUST INSTALLATION

OUTLET

 

 

 

H318I

NOTE: Where the exhaust duct pierces a

3

51 mm (2 in.) Minimum or Clearance per Local

combustible wall or ceiling, the opening must be

 

Codes

 

sized per local codes.

4

No Screen or Cap

 

Wall

5

Clean Out Cover – Inspect Monthly

Figure 31

1

WARNING

To reduce the risk of fire and the accumulation of combustion gases, DO NOT

2

3

exhaust dryer air into a window well, gas vent, chimney or enclosed, unventilated area, such as an attic, wall, ceiling, crawl space under a building or concealed space of a building.

W045

CONNECT TO DRYER

5

4

 

VERTICAL EXHAUST INSTALLATION

H319I

1No Screen or Cap

2Roof

3Wall

451 mm (2 in.) Minimum or Clearance Per Local Codes

5NOTE: Where the exhaust duct pierces a combustible wall or ceiling, an opening must be sized as shown or per local codes.

Figure 32

Duct

Minimum Diameter of

Station

Collector Duct

 

 

A

102 mm (4 inches)

 

 

B

203 mm (8 inches)

 

 

C

229 mm (9 inches)

 

 

D

254 mm (10 inches)

 

 

E

279 mm (11 inches)

 

 

F

305 mm (12 inches)

 

 

G

326 mm (13 inches)

 

 

H

356 mm (14 inches)

 

 

I

381 mm (15 inches)

 

 

J

381 mm (15 inches)

 

 

K

406 mm (16 inches)

 

 

802031

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

31