Installation
5
1
A B C D E F G H I J K
2
3
30°
1
2
AIR
FLOW
4
EXHAUST AIR FLOW
MAXIMUM LENGTH OF DUCT
9.1 m (30 feet)
|
|
| EXHAUST |
HORIZONTAL EXHAUST INSTALLATION | OUTLET | ||
|
|
| H318I |
NOTE: Where the exhaust duct pierces a | 3 | 51 mm (2 in.) Minimum or Clearance per Local | |
combustible wall or ceiling, the opening must be |
| Codes |
|
sized per local codes. | 4 | No Screen or Cap |
|
Wall | 5 | Clean Out Cover – Inspect Monthly |
Figure 31
1
WARNING
To reduce the risk of fire and the accumulation of combustion gases, DO NOT
2
3
exhaust dryer air into a window well, gas vent, chimney or enclosed, unventilated area, such as an attic, wall, ceiling, crawl space under a building or concealed space of a building.
W045
CONNECT TO DRYER
5 | 4 |
|
VERTICAL EXHAUST INSTALLATION
H319I
1No Screen or Cap
2Roof
3Wall
451 mm (2 in.) Minimum or Clearance Per Local Codes
5NOTE: Where the exhaust duct pierces a combustible wall or ceiling, an opening must be sized as shown or per local codes.
Figure 32
Duct | Minimum Diameter of |
Station | Collector Duct |
|
|
A | 102 mm (4 inches) |
|
|
B | 203 mm (8 inches) |
|
|
C | 229 mm (9 inches) |
|
|
D | 254 mm (10 inches) |
|
|
E | 279 mm (11 inches) |
|
|
F | 305 mm (12 inches) |
|
|
G | 326 mm (13 inches) |
|
|
H | 356 mm (14 inches) |
|
|
I | 381 mm (15 inches) |
|
|
J | 381 mm (15 inches) |
|
|
K | 406 mm (16 inches) |
|
|