Exhaust System Maintenance
The dryer interior and the complete exhaust system should be inspected after one year of use and cleaned if necessary. Inspect and clean exhaust duct every one to two years as required thereafter. The weather hood should be checked frequently to make sure the dampers move freely, dampers are not pushed in and that nothing has been set against them. This maintenance work should be done by a qualified service person.
WARNING
To reduce the risk of electric shock, disconnect the electrical service to the unit before cleaning.
W476
Exhausting the unit in
.
SWD576N
521P3 FLEXIBLE METAL VENT KIT
SWD576N
Figure 28
Installation
Dryer Airflow
Efficient dryer operation requires proper dryer airflow. Proper dryer airflow can be evaluated by measuring the static pressure.
Static pressure in the unit’s exhaust duct should be no greater than that shown in Figure 29. (Check with dryer running and no load.)
NOTE: This can be measured with a manometer placed on the exhaust duct approximately 610 mm (2 feet) from the unit. Refer to Figure 29.
.
MAXIMUM STATIC
PRESSURE IN
WATER COLUMN
110 mm (0.4 in.)
2
MEASURING STATIC PRESSURE
D012I
1Manometer
2Exhaust Duct
Figure 29
802031 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 29 |