Global Setup

Cool Down Menu

Temperature

100

°F

 

 

 

 

m

 

 

Time

2

 

 

 

 

 

Cool Down

TMB1321R

Figure 36

The Cool Down Menu gives the user the option to setting the Cool Down Target Temperature and Time.

The or keypads are used to move the highlighted box between the two items in the Cool Down Menu. Once the item is highlighted, the value

can be changed using the and keypads.

Pressing the or keypad will jump to the

Save Changes Menu. Press or to move

highlighted box to “Yes” or “No”. Press the keypad to return to Global Setup Menu. If no changes

were made, press the or keypad to return to Global Setup Menu.

Moisture Menu (if equipped)

Advanced Options for

No

Moisture Dry

 

 

Display Moisture Sensor

Yes

Error

Moisture

TMB1362R

Figure 37

The Moisture Menu allows the user to enable or disable Advanced Options for Moisture Dry (only available on units equipped with moisture sensing feature) and Display Moisture Sensor Error. Enabling Advanced Options for Moisture Dry allows users to program Time Past Target which is the added number of minutes of heat time past the cycle target moisture level while in Cycle Programming.

With Display Moisture Sensor Error option enabled, the control will allow the Moisture Sensor Error to be

displayed in the event that one occurs. Press the

and keypads to move the highlighted box. Press

the or keypad to change selections.

Press the or keypad to jump to the Save

Changes Menu. Use or to move highlighted box to “Yes” or “No”.

Press the keypad to return to Global Setup

Menu. If no changes were made, press or keypad to return to Global Setup Menu.