Alliance Laundry Systems TMB1276C manual Diagnostics, Diagnostic Menu, Test Menu, Test Cycle Menu

Models: TMB1276C

1 44
Download 44 pages 15.59 Kb
Page 34
Image 34

Diagnostics

Diagnostic Menu

Test

 

Alarms

 

 

 

Machine ID

Diagnostic Menu

TMB1325R

Figure 40

The Diagnostic Menu contains Test, Alarm and Machine ID Menus. The menus contain specific diagnostic information and manufacturing data for the

machine. The , , and keypads

position the highlighted box. Press the keypad to select the menu choice.

Press the keypad while in the Diagnostic Menu to return to System Menu.

Test Menu

Diagnostics Are Disabled

Test Cycle

 

Inputs and

 

Outputs

 

 

 

 

 

Test Menu

TMB1326R

Figure 41

The Test Menu provides features for manufacturing and customer service testing. The highlighted box is

moved horizontally and vertically using the

and keypads. Press the keypad to select the menu choice.

Press the keypad to return to Diagnostic Menu.

The screen will display “Diagnostics Are Disabled” if the manual diagnostics have been programmed off. Diagnostic test commands via PDA and network will still function.

Test Cycle Menu

The Test Cycle Menu is used to run several test steps as well as a ten-minute cycle. Step 01 keypad test requires the user to press each keypad. Step 02 Door Status shows whether the loading and lint doors are open or closed. Press any key to advance. Step 03 Screen Test shows four screens that test the LCD screen. Press any key to advance through each of the four test steps.

The Test Cycle Menu for Test Steps 4-13 is shown in Figure 42.

Outputs:

 

DM FM FW RV

HT

EA

IR

 

 

Intputs:

 

 

DR

LD AFS FCRS FCLS

CL

SL1

SL2 IL

RS

DIP1 DIP2 DIP3 DIP4 DIP5 DIP6 DIP7 DIP8

Temp:90 F

RPM:0

 

Moisture:1%

Step04: Temp Index - 50, 75 -170 (12)

PRESS

Test Cycle

TMB1424R

Figure 42

It is similar to the Inputs/Outputs Menu except that the test step is shown at the bottom of the display and a key press prompt message is shown in the lower right

corner. Press to advance through the steps. Refer

to Table 3 for more details of each step. Press to terminate the test.

32

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

70444801

Page 34
Image 34
Alliance Laundry Systems TMB1276C manual Diagnostic Menu, Test Menu, Diagnostics Are Disabled, Test Cycle Menu