End of Cycle Mode
The control enters End of Cycle Mode after the cool down segment is finished. The display will show a graphic prompting the user to open the loading door. If the door has not been opened or a keypad has not been pressed after two minutes, the machine will enter Extended Tumble Mode. This mode is exited when the
door is opened or a or keypad is pressed. The control will then return to Idle Mode.
Extended Tumble Mode
The Extended Tumble Mode has two portions. The
If the door hasn’t been opened and no keys have been pressed one hour after the
UniLinc Identification
Reversing Mode (reversing models only)
Models equipped with the reversing feature will rotate in the forward direction, pause, rotate in the reverse direction and then pause for programmable times and segments of the cycle. Factory default reversing rotate time is 120 seconds and reversing stop time is 6 seconds for all cycles with reversing enabled.
Entering Diagnostic Mode From Idle Mode
When entered from the Idle Mode, the control will be running a test selected by the user via keypad presses or communication with a device. The diagnostic tests available from the Idle Mode are the Test Cycle and Inputs Outputs Menus.