Alliance Laundry Systems TMB1276C manual 3029, Inputs Outputs Menu

Models: TMB1276C

1 44
Download 44 pages 15.59 Kb
Page 36
Image 36

Diagnostics

Inputs Outputs Menu

Outputs:

 

DM FM FW RV

HT

EA

IR

 

 

Intputs:

 

 

DR

LD AFS FCRS FCLS

CL

SL1

SL2 IL

RS

DIP1 DIP2 DIP3 DIP4 DIP5 DIP6 DIP7 DIP8

Temp:180 F RPM:25

 

Moisture:30%

Inputs Outputs

30:29

TMB1425R

Figure 43

When the Inputs Outputs Menu is accessed through the Diagnostic Menu, the user can manually turn on outputs. The user can scroll through the outputs using any of the arrow keys, the cursor is indicated by flashing the active output on the screen. The user must

“setup” the outputs to be turned on. The keypad is used to select individual outputs to be turned on or

off. After the keypad is pressed the control will turn the selected outputs on and display the text “RUNNING”. The outputs cannot be selected until

the keypad is pressed. The text “RUNNING” is no longer displayed. The screen will still show the selected outputs on the screen and the user can again

select outputs to be turned on or off. If the or

keypad is pressed at any time during this test, the control will turn off all outputs if the test is running or return to the previous screen if the test is not running.

If the Inputs Outputs Menu is accessed through the

Run Diagnostic Menu (pressing the keypad during a running cycle) the menu shows only what is turned on and off as the cycle runs. Refer to Figure 43.

Abbreviations for the Inputs and Outputs are defined in the following table:

 

Inputs

 

 

DR

Loading Door

 

 

LD

Lint Door

 

 

AFS

Airflow Switch

 

 

FCRS

Fan Motor Contactor Switch

 

 

FCLS

Fan Motor Centrifugal Switch

 

 

CL

Cabinet High Limit

 

 

SL1

Store 1 High Limit

 

 

SL2

Store 2 High Limit

 

 

IL

Ignition Lockout

 

 

RS

Rotation Sensor

 

 

DIP1

Dip Switch 1

 

 

DIP2

Dip Switch 2

 

 

DIP3

Dip Switch 3

 

 

DIP4

Dip Switch 4

 

 

DIP5

Dip Switch 5

 

 

DIP6

Dip Switch 6

 

 

DIP7

Dip Switch 7

 

 

DIP8

Dip Switch 8

 

 

Temp

Temperature

 

 

RPM

Rotations per Minute

 

 

Moisture

Moisture Level

 

 

 

Outputs

 

 

DM

Damper Motor

 

 

FM

Fan Motor

 

 

FW

Forward Contactor

 

 

RV

Reverse Contactor

 

 

HT

Heater

 

 

EA

External Alarm

 

 

IR

Ignition Reset

 

 

 

Table 4

34

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

70444801

Page 36
Image 36
Alliance Laundry Systems TMB1276C manual 3029, Inputs Outputs Menu