Camera interfaces

Outputs DOLPHIN

The DOLPHIN cameras have 3 inverted outputs with open collectors. These are shown with external wiring in the following diagram:

Figure 28: Output schematics with external resistor R (DOLPHIN)

Parameter

Test condition

Value

 

 

 

Collector voltage

 

Max. 500 mA

Emitter collector voltage

 

Max. 45 V

Figure 29: Output parameters (DOLPHIN)

OutVCC

Resistor value

 

 

5 V

470 Ω

 

 

12 V

1 kΩ

 

 

24 V

2.2 kΩ

 

 

Figure 30: OutVCC (DOLPHIN)