Allied International Home Security System Voltages above +30 V may damage the optical coupler

Models: Home Security System

1 63
Download 63 pages 38.74 Kb
Page 51
Image 51

Camera interfaces

= 5 V

 

Input signal

 

> 5 V

10 k

 

External resistor

 

(outside camera)

 

See warning above

 

Input

Polarity

selectable

via software

Input state

Figure 25: Input block diagram (GUPPY)

PIKE The inputs can be connected directly to +5 V. If a higher voltage is used, an external resistor must be placed in series. Use at +12 V a 820 Ω resistor and at +24 V a 2.2 kΩ resistor.

Caution PIKE

Voltages above +45 V may damage the optical coupler.

STINGRAY The inputs can be connected directly to +3 V ... + 30 V. (STINGRAY)

Caution STINGRAY

Voltages above +30 V may damage the optical coupler.

ALL CAMERAS The following note is valid for all cameras:

Note

ALL CAMERAS

 

For information on the optical coupler, polarity and the IO

 

registers see the Technical Manuals.

Hardware Installation Guide V2.0.0

51

Page 51
Image 51
Allied International Home Security System manual Voltages above +30 V may damage the optical coupler