Safety instructions

PIKE/STINGRAY GOF connectors

Caution

Special warning for all PIKE/STINGRAY models with GOF

 

connectors:

 

 

GOF connectors are very sensitive. Any dust or dirt may

 

cause damage.

Always keep the GOF connector and optical fiber plug clean.

If GOF connection is not in use, keep GOF dust cover on the GOF connector.

Reduce mating cycles to a minimum to prevent abra- sion.

Please note that optical fiber cables have a very limited deflection curve radius.

PIKE/STINGRAY voltages

The inputs can be connected directly to +5 V. If a higher voltage is used, an external resistor must be placed in series. Use at +12 V a 820 Ω resistor and at +24 V a 2.2 kΩ resistor.

Caution PIKE/STINGRAY

Voltages above +45 V may damage the optical coupler.

GUPPY voltages

Caution GUPPY

If using voltages higher than + 5 V the input of the cam- era will be damaged.

To avoid damage of the input, use an external resistor in series (outside of the camera).

Recommendations for resistors by voltages higher than + 5 V:

Use at +12 V a 18 kΩ resistor.

Use at +24 V a 47 kΩ resistor.

For details see Figure 1: Input block diagram (GUPPY) on page 16.

Hardware Installation Guide V2.0.0

15

Page 15
Image 15
Allied International Home Security System manual PIKE/STINGRAY GOF connectors, PIKE/STINGRAY voltages, Guppy voltages