Allied Telesis R800 Series Features in, Patch file details for Patch 86222-08 are listed in Table

Models: R800 Series

1 30
Download 30 pages 8.55 Kb
Page 21
Image 21
Patch file details for Patch 86222-08 are listed in Table 14.

Patch 86222-22 For Rapier Switches and AR800 Series Modular Switching Routers

21

PCR: 01246

Module: SWI

Network affecting: No

The default setting for the switch port parameter INFILTERING is now OFF, as specified in IEEE802.1Q. A VLAN will still reject these packets if they are not from valid VLAN member ports.

PCR: 01247

Module: IPG

Network affecting: No

The IGMP snooping forwarding process now correctly selects outgoing ports when DVMRP is managing the multicast routing information.

PCR: 01248

Module: SWI

Network affecting: No

A configuration problem prevented trunking of gigabit ports at 100Mbit speeds. This issue has been resolved. The A39 gigabit copper uplink reverted to autonegotiation after a restart, even if it was configured to a fixed speed. This issue has been resolved. When the port has been configured for a fixed speed, the mode is now set to MDIX, not MDI.

PCR: 01254

Module: PRI

Network affecting: No

When an M2 version of the AR020 PRI E1/T1 PIC was installed in a AR040 NSM it was not possible to select the T1 mode of operation regardless of the jumper setting. This issue has been resolved.

PCR: 01256

Module: Firewall

Network affecting: No

A fatal error occurred when the firewall discarded disallowed multicast packets. This issue has been resolved.

Features in 86222-08

Patch file details for Patch 86222-08 are listed in Table 14.

Table 14: Patch file details for Patch 86222-08.

Base Software Release File

86s-222.rez

 

 

Patch Release Date

09-Nov-2001

 

 

Compressed Patch File Name

86222-08.paz

 

 

Compressed Patch File Size

291012 bytes

 

 

Patch 86222-08 includes all issues resolved and enhancements released in previous patches for Software Release 2.2.2, and the following enhancements:

PCR: 01201

Module: L2TP

Network affecting: Yes

Tunnel creation failed when attempting to establish a point-to-point tunnel from an ATR router (tunnel originator) to another vendor’s router. This issue has been resolved.

Patch 86222-22 for Software Release 2.2.2 C613-10319-00 REV U