Patch 86222-22 For Rapier Switches and AR800 Series Modular Switching Routers

15

Features in 86222-14

Patch file details are listed in Table 8.

Table 8: Patch file details for Patch 86222-14.

Base Software Release File

86s-222.rez

 

 

Patch Release Date

28-Feb-2002

 

 

Compressed Patch File Name

86222-14.paz

 

 

Compressed Patch File Size

335336 bytes

 

 

Patch 86222-14 includes all issues resolved and enhancements released in previous patches for Software Release 2.2.2, and the following enhancements:

PCR: 02005

Module: IPG

Network affecting: No

When telnetting to the switch, the TCP connection was reset, and when the packet was passed to IPG_Forward a fatal error occurred. This patch implements a workaround.

PCR: 02035 Module: VLAN

Network affecting: No

The CREATE CONFIG command now correctly configures tagged ports belonging to VLANs not in the default STP.

PCR: 02036

Module: SWITCH

Network affecting: No

A new command allows the Layer 3 aging timer to be changed:

SET SWITCH L3AGEINGTIMER=<seconds>

where seconds can be 30 - 43200. After each cycle of the ageing timer, all existing Layer 3 entries with the hit bit set will have the hit bit reset to zero, and all existing Layer 3 entries with the hit bit set to zero will be deleted.

The SHOW SWITCH command output now displays the Layer 3 ageing timer value.

PCR: 02038

Module: PING

Network affecting: No

Resolution of PCR 02011 in Patch 12 sometimes caused a fatal error. This issue has been resolved.

PCR: 02039

Module: IPG

Network affecting: No

The SHOW IP ROUTE FILTER command output displayed counters for 'passes' and 'include' that were the same. This issue has been resolved. Counters now increment only when a filter is active and do not count interface routes.

PCR: 02040

Module: SWI

Network affecting: No

PCR 02019 permitted the reception of packets by the CPU that should have been discarded. This issue has been resolved.

PCR: 02057

Module: FIREWALL

Network affecting: No

Firewall TCP timeout values have been reduced for sessions placed in the CLOSED state after receiving a TCP/RESET. This applies to the stateful inspection of firewall sessions only, and not to the TCP module. Previously, PCR 01263 reduced the timeout value for sessions placed in the CLOSED state after a TCP/FIN packet was received.

Patch 86222-22 for Software Release 2.2.2 C613-10319-00 REV U

Page 15
Image 15
Allied Telesis R800 Series manual PCR 02035 Module Vlan Network affecting No, PCR Module Switch Network affecting No