Patch | 25 |
PCR: 01229 | Module: SWI | Network affecting: No |
The CREATE CONFIG command did not include all required L3FILTER | ||
parameters in the generated script file. |
| |
PCR: 01232 | Module: SWI | Network affecting: No |
The L3 table on the Rapier G6 is now cleared when a switch port goes down | ||
to ensure the L3 and ARP tables are consistent. |
| |
PCR: 01234 | Module: SWI | Network affecting: No |
A switch port that was transmitting STP BPDUs and also mirroring its transmit traffic to the mirror port caused a fatal error. This issue has been resolved.
Features in
Patch file details for Patch 86222-06 are listed in Table 16.
Table 16: Patch file details for Patch
Base Software Release File | |
|
|
Patch Release Date | |
|
|
Compressed Patch File Name | |
|
|
Compressed Patch File Size | 226776 bytes |
|
|
Patch
PCR: 01188 | Module: SWI | Network affecting: No |
The power supply voltages of the base board PHYs on a Rapier G6 are controlled by a PHY register value, which was incorrectly set. This issue has been resolved.
PCR: 01190 | Module: PIM | Network affecting: No |
In PIM Dense Mode, if a data stream started before PIM hello messages were exchanged, the receiver did not get the data stream. This issue has been resolved.
PCR: 01192 | Module: SWI | Network affecting: No |
The Rapier G6 base ports sometimes experienced spurious link up or link down events. This issue has been resolved.