Altinex MT105-120/121 manual Off, Multi-Tasker

Models: MT105-120/121

1 23
Download 23 pages 56.69 Kb
Page 14
Image 14
11.[OFF]

MULTI-TASKER™

11.[OFF]

This command disables one or more outputs for a single card or a group of cards.

SINGLE CARD OPERATION

Command Format: [OFFmCnUi]

m= Output (m = # from 1 to max outputs) Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

Card 5 has Output 1 ON. The following commands may be used to turn OFF the output.

1)

[OFF1C5]:

Turns OFF Output 1 only.

2)

[OFF23C5]:

Turns OFF Outputs 2 and 3.

3)

[OFFC5]:

Turns OFF all outputs.

GROUP OPERATION

Command Format: [OFFmGkUi]

This command disables output "m" for each card in group "k" of unit "i".

m= Output (m = # from 1 to max outputs) Gk = Group ID (k = # from 1-8)

Ui = Unit ID (i = # from 0-9)

Example:

1.[OFF1G1]: Turns OFF Output 1 for each card in group 1.

2.[OFFG1]: Turns OFF all outputs for each card in group 1.

PATH OPERATION

Command Format: [OFFmCnUiP]

This command will set the path for the output, but it is not active until the switch command, [SW], is executed. Commands ending in "P" are not executed immediately. The path for outputs on multiple cards or the same card may be preloaded.

m= Output (m = # from 1 to max outputs) Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

P= Path

Example:

There are two MT105-120cards in slots 6 and

7.Disable Output 1 of card 6 and Output 3 of card 7 simultaneously using the following commands:

[OFF1C6P]

[OFF3C7P]

[SW]

If "F" is included, use the [OFFmCnPF] command or the [OFFmCnFP] command.

FEEDBACK OPERATION

Command Format: [OFF…..F]

After processing a command, an OK or ER will be returned as feedback if "F" is included at the end of a command string.

Example:

[OFF1C2F]: if path is not set

[OFF1C2PF]: if path is set

12. […S] – SAVE

This command will save the configuration

command being sent in memory. When sending the command [I1O1C4S], after reset or power up, Input 1 will be connected to Output 1 on C4. This command only saves the Input 1 to Output 1 connection above. In order to save all the current settings, use the [CnS] command.

13. […F] – FEEDBACK

After processing a command, an OK or ER will be returned as feedback if "F" is included at the end of a command string.

400-0362-003

13