Altinex MT105-120/121 manual MATmXnCi, Test, Help, 21. WR, Multi-Tasker

Models: MT105-120/121

1 23
Download 23 pages 56.69 Kb
Page 16
Image 16
18.[MATmXnCi]

MULTI-TASKER™

18.[MATmXnCi]

This Matrix command allows the switcher card to be setup for different matrix sizes.

m = number of inputs (8,4,2)

n = number of outputs (8,4,2,1)

Command Format: [TESTCnUi]

Cn = Card ID (n = slot # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

There is an MT105-120in slot #4. Send the

i = card number (1-20)

 

MT105-120

 

 

8 X 8

 

Input

 

Output

O5

O1

 

O1

 

O5

O6

O2

 

O2

O6

O7

O3

 

O3

O7

O8

O4

 

O4

O8

 

MT105-120

 

4 X 4

Input

 

 

Output

O3a

O1a

 

 

O1a

O3a

O3b O1b

 

 

O1b O3b

O4a O2a

 

 

O2a O4a

O4b O2b

 

 

O2b O4b

 

MT105-120

 

2 X 2

Input

 

 

Output

O2a

O1a

 

 

O1a

O2a

O2b

O1b

 

 

O1b O2b

O2c

O1c

 

 

O1c O2c

O2d

O1d

 

 

O1d O2d

19.[TEST]

MT105-121

8 X 4

Input Output

O5 O1 19.[TEST]20.[HELP] O1

O6 O2 21.[WR]Manual background O2

O7 O3 Manual backgroundManual background O3

O8 O4 Manual backgroundManual background O4

MT105-121

4 X 2

Input Output

O3a O1a Manual backgroundManual background O1a

O3b O1b Manual backgroundManual background O1b

O4a O2a Manual backgroundManual background O2a

O4b O2b Manual backgroundManual background O2b

MT105-121

2 X 1

Input Output

O2a O1a Manual backgroundManual background O1a

O2b O1b Manual backgroundManual background O1b

O2c O1c Manual backgroundManual background O1c

O2d O1d Manual backgroundManual background O1d

command [TESTC4] to test the internal memory.

20.[HELP]

This command displays information available for the Multi-Tasker interface commands.

Command Format: [HELPCnUi]

Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

In order to display the RS-232 commands available for the MT105-120/121card in slot #2, send the command [HELPC2]. The commands along with a brief description will be displayed in the Terminal Window.

21.[WR]

This command groups multiple cards in the enclosure allowing all the group members to be controlled simultaneously with the same command. Each unit may define a maximum of eight groups.

In Multi-Tasker™ systems with audio and video cards, boards are typically grouped as follows:

Group 1 = Video Cards

Group 2 = Audio Cards

This command performs a test on the internal memory. Upon completion, the system will display the results. If there are no problems, the system will display the following:

MEMORY IS GOOD

Otherwise, failures will be indicated.

Group 3 = Video and Audio Cards

If assigning group commands to button functions, it is best to use the "Press and Hold on Power Up" to make group settings.

400-0362-003

15

Page 16
Image 16
Altinex MT105-120/121 manual MATmXnCi, Test, Help, 21. WR, Multi-Tasker