![25.[RDN]](/images/new-backgrounds/27575/2757531x1.webp)
MULTITASKER™
Command Format: [RUP=xxCnUi]
xx = Stop Level (xx = # from
Cn = Card ID (n = # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
Ramp the output volume from a starting level of 1 up to 10. Send the command [RUP=10C8] and receive the following feedback:
[02][03][04]…[10]
25.[RDN]
This command ramps the OUTPUT volume down to a level of 1 at a rate defined using the [RAMP] command.
Command Format: [RDNCnUi]
Cn = Card ID (n = # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
Ramp the output volume from a starting level of 16 down to 1 for the card in slot #8. Send the command [RDNC8] and the system will respond with the following feedback:
[16][15][14]…[01]
26.[RDN=]
This command ramps the OUTPUT volume down to a user defined level at a rate defined using the [RAMP] command.
Command Format: [RDN=xxCnUi]
xx = Stop Level (xx = # from
Cn = Card ID (n = # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
Ramp the output volume from a starting level of 16 down to 8 for the card in slot #8. Send the command [RDN=8C8] and the system will respond with the following feedback:
[16][15][14]…[8]
27.[RST]
This command stops ramping and maintains the last volume setting.
Command Format: [RSTCnUi]
Cn = Card ID (n = # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
The card in slot #8 is ramping from 1 to 16. Send the command [RSTC8] and the card will stop ramping the volume. The last displayed volume setting is the new volume level.
28.[RAMP]
This command displays the ramping time for 16 steps. The time between each step is equal to the time in seconds divided by 16.
Command Format: [RAMPCnUi]
Cn = Card ID (n = # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
Display the ramp rate setting for the card in slot #8 by sending [RAMPC8]. The system will respond with feedback similar to the following:
RAMPTIME = 6 SECONDS
29.[RAMP=]
This command sets the ramp rate for 16 steps. The settings range from 4 to 18 seconds, in
Command Format: [RAMP=xCnUi]
x | = | Rate in Seconds | |
|
| 4 | = 0.25 seconds/step |
|
| 6 | = 0.38 seconds /step |
|
| 8 | = 0.50 seconds /step |
|
| 10 | = 0.63 seconds /step |
|
| 12 | = 0.75 seconds /step |
|
| 14 | = 0.88 seconds /step |
|
| 16 | = 1.00 seconds /step |
|
| 18 | = 1.13 seconds /step |
Cn | = Card ID (n = # from 1 to max slots) | ||
Ui | = | Unit ID (i = # from 0 to 9) |
15 |