Troubleshooting B

Overview

B-1

Overview

This appendix points out basic problems that can occur when operating a 392xPlus modem. Use Tables B-1 through B-6 to check out these problems. If you are having data communication difficulties, such as periodic character loss, random errors, or constant format errors, use the loopback tests described in the Test section of Chapter 4. With these tests you can usually isolate the fault in your system by using the process of elimination. If problems continue to occur, contact your service representative.

 

Table B-1

 

Modem Health

 

 

Symptom

Action

 

 

The modem did not pass the

Contact your service representative.

power-up self-test.

 

 

 

The power LED does not light or the

Make sure the modem's ON/OFF switch is in the ON position.

LCD does not display information.

Make sure the power supply is connected to the dc power receptacle on the

 

 

modem.

 

If the Power LED and/or LCD do not operate, contact your service

 

representative.

 

 

A problem is suspected after the

Perform a self-test via the modem's DCP or type AT&T9 if using AT commands.

power-up self-test.

Perform a local analog loopback with a Pattern test. If the modem consistently

 

 

registers errors, contact your service representative.

 

If the modem passes the above tests and a problem still exists, then the

 

problem is probably not with your modem.

 

 