COMSPHERE 392xPlus Modems

Self

Self performs an internal self-test of the modem, which takes less than a minute to complete. The modem must be offline; otherwise, Invalid Command appears.

WARNING

When this test is run in Remote mode, it causes the Remote mode session to be lost. The Remote mode session will reestablish after the self-test completes (usually one or two minutes). If the remote self-test fails, a Device Failure alarm message appears when the remote modem's Device Health and Status (DeviceHS) branch is accessed.

To access Self from the Test branch, make the following selection:

Test:

 

>

Abort

 

Self

F1

F2

F3

Select Self. (All LCD cells and DCP status indicators light.)

NOTE

The test delays 15 to 30 seconds to allow any outstanding network management messages to propagate before the VF channel is interrupted by the test.

If the modem passes the self-test, Pass appears on the LCD. If it fails, Failed appears. If the modem fails, contact your service representative. If Invalid Command appears, the modem is operating on dial lines. If OtherTestActive appears, another test is in progress. If another test is in progress, select Abort to clear the current test and try again. If the modem is operating on dial lines, disconnect to clear the dial lines, and then choose Self. If the modem receives a ring signal during this test, the test is canceled and RI Abort message appears.

To exit this function and remain in the Test branch, press the key. To exit and return to the

Top-Level menu, press the key.

3-56

November 1996

3920-A2-GN31-30

Page 93
Image 93
Paradyne 392xPLUS operation manual Self