DCP Configuration
Test Ð Multiport l
The Test configuration option determines the duration of a test.
Table
Table
Test Configuration Options Ð Multiport Mode l
Test Timeout: Disable
End Disable 30sec 60sec 240sec
Test
Disable ± Allows a test to run indefinitely.
30, 60, or 240 seconds ± Allows the test to run for 30 seconds, 60 seconds, or 240 seconds.
V54 Address: Disable
Nxt Disable (Address Values)
V.54 Address. Determines which remote 392xPlus modem is placed into a remote loopback test. This test can be either a remote digital loopback or local analog loopback. This type of addressing should be used for extended data circuits (tail circuits).
Disable ± This is used for normal
Address Values ± 01, 03, 05, 07, 09, 0B, 0D, 0F, 11, 13, 15, 17, 19, 1B, 1D, 1F, 25, 27, 2B, 2D, 2F, 33, 35, 37, 3B, 3D, 3F, 55, 57, 5B, 5F, 6F, 77, or 7F. This configuration option selects the address of a modem that is to be placed into a loopback test. This configuration option is used for more complex networks where multiple modems, used in extended data circuits (tail circuits), can be commanded to loopback.
The AT command for Disable is
The AT command for V.54 Address is
V54 Device Type: Peripheral
End Peripheral Intermediate
This configuration option only appears when V54 Address is enabled.
V.54 Device Type. Identifies where the modem is physically located in the network.
Peripheral ± The modem is located at the endpoint of the network and is not connected
Intermediate ± The modem is either of the two modems connected
The AT command for Peripheral is
The AT command for Intermediate is