COMSPHERE 392xPlus Modems
Table
(1 of 12)
392xPlus S-Registers
Description | DCP LCD | |
Command | ||
|
| Sequence |
|
|
|
S0 | Configure\Edit\ | |
| will count before automatically answering a call. | Line Dialer |
| Enter zero (0) if you do not want the modem to automatically answer any calls. |
|
| Otherwise, enter a value from 1±255 for the number of rings to count before |
|
| answering. The factory setting is 1. |
|
|
|
|
S2 | AT Escape Character. Register determines ASCII value used for escape | Configure\Edit\ |
| sequence to enter Command mode from Data mode. | DTE Dialer |
| Enter a value from 0 to 127 for the escape character. Any value greater than |
|
| 127 causes the modem to disable the escape sequence. When the escape |
|
| sequence is disabled, the modem cannot return to Command mode until the |
|
| call is disconnected. The factory setting is 43 (+ key). |
|
|
|
|
S3 | Carriage Return Character. Register determines ASCII value used as the | Configure\Edit\ |
| carriage return (Return key). This character is used to end command lines and | DTE Dialer |
| result codes. |
|
| Enter a value from 0 to 127 for the command end character. The factory |
|
| setting is 13 (carriage return key). |
|
|
|
|
S4 | Line Feed Character. Register determines ASCII value used as the line feed | Configure\Edit\ |
| character. | DTE Dialer |
| Enter a value from 0±127 for the line feed character. The factory setting is 10 |
|
| (ASCII carriage return or line feed). |
|
|
|
|
S5 | Backspace Character. Register determines ASCII value used as the | Configure\Edit\ |
| backspace (Backspace key). This character moves the cursor to the left and | DTE Dialer |
| erases the previous character. |
|
| Enter a value from 0±127. The factory setting is 8 (backspace key). |
|
|
|
|
S6 | Blind Dial Pause1. Register determines how long (in seconds) the modem | Configure\Edit\ |
| waits after going | Line Dialer |
| code X0, X1, or X3. |
|
| Enter a value from 2±255 seconds. The factory setting is 2. |
|
|
|
|
S7 | No Answer | Configure\Edit\ |
| originating modem waits before abandoning a call when no answer tone is | Line Dialer |
| received. |
|
| Enter a value from 1±255 seconds. The factory setting is 45. |
|
|
|
|
S8 | ª,º Pause Time for the Dial Modifier. Register determines how long (in | Configure\Edit\ |
| seconds) the modem pauses when it encounters a comma (,) in the Dial | Line Dialer |
| command string. |
|
| Enter a value from 0±255 seconds. The factory setting is 2. |
|
|
|
|
S10 | No Carrier Disconnect1. Register determines how long (in tenths of seconds) | Configure\Edit\ |
| the modem allows the carrier signal to be OFF before disconnecting the call. | Line Dialer |
| Enter a value from 0±254 in 0.1 second increments. A value of 255 disables |
|
| this register. The factory setting is 20 (2 seconds). |
|
|
|
|
1 The range of allowable values may be restricted in some countries.
November 1996 |