COMSPHERE 392xPlus Modems

Table 5-3

(1 of 12)

392xPlus S-Registers

S-Register

Description

DCP LCD

Command

 

 

Sequence

 

 

 

S0

Auto-Answer Ring Number1. Register determines number of rings the modem

Configure\Edit\

 

will count before automatically answering a call.

Line Dialer

 

Enter zero (0) if you do not want the modem to automatically answer any calls.

 

 

Otherwise, enter a value from 1±255 for the number of rings to count before

 

 

answering. The factory setting is 1.

 

 

 

 

S2

AT Escape Character. Register determines ASCII value used for escape

Configure\Edit\

 

sequence to enter Command mode from Data mode.

DTE Dialer

 

Enter a value from 0 to 127 for the escape character. Any value greater than

 

 

127 causes the modem to disable the escape sequence. When the escape

 

 

sequence is disabled, the modem cannot return to Command mode until the

 

 

call is disconnected. The factory setting is 43 (+ key).

 

 

 

 

S3

Carriage Return Character. Register determines ASCII value used as the

Configure\Edit\

 

carriage return (Return key). This character is used to end command lines and

DTE Dialer

 

result codes.

 

 

Enter a value from 0 to 127 for the command end character. The factory

 

 

setting is 13 (carriage return key).

 

 

 

 

S4

Line Feed Character. Register determines ASCII value used as the line feed

Configure\Edit\

 

character.

DTE Dialer

 

Enter a value from 0±127 for the line feed character. The factory setting is 10

 

 

(ASCII carriage return or line feed).

 

 

 

 

S5

Backspace Character. Register determines ASCII value used as the

Configure\Edit\

 

backspace (Backspace key). This character moves the cursor to the left and

DTE Dialer

 

erases the previous character.

 

 

Enter a value from 0±127. The factory setting is 8 (backspace key).

 

 

 

 

S6

Blind Dial Pause1. Register determines how long (in seconds) the modem

Configure\Edit\

 

waits after going off-hook before dialing a telephone number if using result

Line Dialer

 

code X0, X1, or X3.

 

 

Enter a value from 2±255 seconds. The factory setting is 2.

 

 

 

 

S7

No Answer Time-out1. Register determines how long (in seconds) an

Configure\Edit\

 

originating modem waits before abandoning a call when no answer tone is

Line Dialer

 

received.

 

 

Enter a value from 1±255 seconds. The factory setting is 45.

 

 

 

 

S8

ª,º Pause Time for the Dial Modifier. Register determines how long (in

Configure\Edit\

 

seconds) the modem pauses when it encounters a comma (,) in the Dial

Line Dialer

 

command string.

 

 

Enter a value from 0±255 seconds. The factory setting is 2.

 

 

 

 

S10

No Carrier Disconnect1. Register determines how long (in tenths of seconds)

Configure\Edit\

 

the modem allows the carrier signal to be OFF before disconnecting the call.

Line Dialer

 

Enter a value from 0±254 in 0.1 second increments. A value of 255 disables

 

 

this register. The factory setting is 20 (2 seconds).

 

 

 

 

1 The range of allowable values may be restricted in some countries.

5-16

November 1996

3920-A2-GN31-30

Page 201
Image 201
Paradyne 392xPLUS operation manual 392xPlus S-Registers Description