392xPlus S-Registers
| Description | DCP LCD | |
| Command | ||
|
|
| Sequence |
|
|
| |
S96 | Trellis Multipoint (TMp) Tx Preemphasis. Provides amplification for | Configure\Edit\ | |
| frequencies above the carrier frequency to compensate for high frequency line | Leased | |
| attenuation. |
| |
| Register has the following values: |
| |
| 0 | = Enable |
|
| 1 | = Disable |
|
| The factory setting is Enable. |
| |
|
|
| |
S97 | Reduced Asynchronous Buffer Size. Register limits the modem's buffer size to | Configure\Edit\ | |
| a maximum of 20 characters. | V42/MNP/Buffer | |
| Register has the following values: |
| |
| 0 | = Disable |
|
| 1 | = Enable |
|
| The factory setting is Disable. |
| |
|
|
| |
S98 | Special Standby. Supports automatic dial standby when a third modem is used | Configure\Edit\ | |
| for dial backup. | Leased | |
| Register has the following values: |
| |
| 0 | = Disable |
|
| 1 | = Enable |
|
| The factory setting is Disable. |
| |
|
|
|
|