DCP Operation
To access Rem_Digital_Loop from the Test branch, make the following selections:
Press the
Test:
Rem_Digital_Loop
F1 F2 F3
key until Rem_Digital_Loop appears. Press any function key to start this test.
Pick Test Port | > |
Port1 | Port2 |
F1 F2 F3
Select the appropriate port by pressing the corresponding function key. Press the other ports into view.
This screen does not appear in Singleport mode.
Test:P1:Rem Loop
Started
key to scroll
F1 F2 F3
The message Started appears on the LCD, and the Test LED lights.
If OtherTestActive appears on the LCD, another test is in progress. Select Abort to clear the current test and try again. If the Test Timeout configuration option is enabled, Test Timeout appears at the conclusion of the test. If it is disabled, the test operates until aborted. For more information on the Test Timeout configuration option, refer to the Test section in Chapter 4.
To exit this function and remain in the Test branch, press the key. To exit and return to the
key.