COMSPHERE 392xPlus Modems

Table 5-2

(3 of 9)

392xPlus AT Commands

AT

 

 

Description

 

DCP LCD

 

 

 

Command

Command

 

 

 

 

 

 

 

 

Sequence

 

 

 

 

 

 

 

 

 

Xn

Extended Result Code, Dial Tone Detect, and Busy Tone Detect Configuration

Extended Result

 

Options.

 

 

 

 

Code:

 

 

 

Extended

Dial Tone

Busy Tone

Configure\Edit\

 

 

 

DTE Dialer

 

 

 

Result Code:

Detect:

Detect:

Dial Tone Detect:

 

 

 

 

 

 

 

X0

 

Disable

Disable

Disable

Configure\Edit\

 

X1

 

Enable

Disable

Disable

Line Dialer

 

X2

 

Enable

Enable

Disable

Busy Tone

 

X3

 

Enable

Disable

Enable

 

X4

 

Enable

Enable

Enable

Detect:

 

X5

 

Add/EC

Enable

Enable

Configure\Edit\

 

X6

 

Add/V42.MNP

Enable

Enable

Line Dialer

 

X7

 

Use DTE Rate

Enable

Enable

 

 

Extended Result Code:

 

 

 

 

 

 

 

 

Enable

 

Displays all result codes listed in Table 5-1 except for error

 

 

 

 

control suffix.

 

 

 

 

Disable

 

Only displays OK, CONNECT, RING, NO CARRIER,

 

 

 

 

ERROR.

 

 

 

 

Add/EC

 

Displays result codes with /EC suffix.

 

 

 

Add/V42,MNP

Displays result codes with V.42 or MNP suffix.

 

 

Use DTE Rate

Displays DTE data rate instead of line rate.

 

 

Dial Tone Detect:

 

 

 

 

 

 

 

 

 

 

Enable

 

Sets the modem for dial tone detect.

 

 

 

 

 

 

 

Disable

 

Sets the modem for blind dialing.

 

 

 

 

 

 

NOTE: It may not be possible to disable Dial Tone Detect in some countries.

 

 

Busy Tone Detect:

 

 

 

 

 

Enable

 

Modem monitors for busy tone.

 

 

 

Disable

 

Modem ignores busy tone.

 

 

 

 

 

 

 

Yn

Long Space Disconnect.

 

 

Configure/Edit/

 

Y0

Disable. Ignores long space.

 

 

Line Dialer

 

 

 

 

 

Y1

Enable. Disconnects if long space is detected. Enables transmission

 

 

 

of a long space.

 

 

 

 

 

 

 

 

Zn

Reset and Load Active.

 

 

Control\Reset

 

Z0

Loads configuration options from Active (Saved) to Active

 

 

 

(Operating).

 

 

 

 

Z1

Loads configuration options from Customer 1 to Active (Operating).

 

 

Z2

Loads configuration from Customer 2 to Active (Operating).

 

 

Z3

Loads configuration options from Active (Saved) to Active

 

 

 

(Operating) and performs a reset.

 

 

 

 

 

 

 

 

 

5-8

November 1996

3920-A2-GN31-30

Page 193
Image 193
Paradyne 392xPLUS operation manual Only displays OK, CONNECT, RING, no Carrier, Error