DCP Operation

When you select SubHS,

xxx Displays the network management address of the downstream modem selected.

yyyyyyDisplays the status of the downstream modem. This message is updated every several seconds to display the latest status. MAJOR, MINOR, and STATUS display Health and Status alarm conditions; refer to Table 3-6 in the Device Health and Status (DeviceHS) section of this chapter for additional information. UNKNWN appears when the modem does not recognize the downstream health and status information or device communication is not established. Normal appears if no alarms are present. NO RSP appears when the downstream modem does not respond to the poll.

Select Nxt to scroll through the entries in the poll lists.

To exit this function and return to the Top-Level menu, press the key.

Call Setup Branch

The Call Setup function is not available in TMp Control mode.

For dial backup applications, the Call Setup branch of the Top-Level menu allows you to dial, disconnect, and answer telephone calls. For leased backup applications, the Call Setup branch allows you to switch between the primary leased line and the backup leased line.

In leased backup operation, a 2-wire leased line is used as the backup facility instead of the normal 2-wire dial line. Plug the leased line into the jack labeled DIAL on the rear panel of the modem (see Figure 2-1 in Chapter 2), and enable the Dual_Leased_Ln configuration option. (Refer to the Leased Line section in Chapter 4 for configuration options.) Except for dialing, ring indication, and call progression functions, you control the backup function as if it were a normal dial backup.

ªStatusº

Status

Configure

PList

Control

Test

(Dial Backup only)

SubHS

Call_Setup

Tlk/Data

Security

Remote

Dial

Disconnect

Answer

Dial_Standby

Change_Directory Directory_Status

 

 

 

or

(Does not appear

 

 

 

Return_to_Dial

 

 

 

in North America)

Directory Locations 1 - 24