DCP Operation

If unsuccessful, the modem remains in the Download Transfer mode. The LCD's top line displays RemClone Failed and the bottom line displays one of the following messages:

Incompat Modulat

The modems are connected, but are using a modulation scheme other

 

than V.34 family, V.33, V.32 family, V.29, or TMp.

No Response

The remote modem is not a 3900 Series modem or the connection

 

between the two modems is poor.

Access Disabled

The remote modem's Access from Remote configuration is disabled.

Password Invalid

The local and remote modems' passwords do not match. Correct the

 

problem and attempt another download from the local modem. If this

 

fails, contact your service representative.

No Circuit

There is no connection between the local and remote modem.

After successful establishment of a Remote Cloning Download session, the following screens appear.

RemClone Status

Initializing

F1 F2 F3

RemClone Status

Bank1:xxxx/yyyy

F1 F2 F3

As the firmware transfers, the local and remote LCD's bottom line displays the status of the download process, plus the number of records sent versus the total number of records for that data bank number.

For Single download applications, if the download is successful, the local modem displays Remote Clone OK and the remote modem displays Frmware Upgrade. If the download took place over the dial network, the modems disconnect when the download is complete.

If the Single download is unsuccessful, RemClone Failed appears on the LCD's top line. Attempt another download from the local modem. If this fails, contact your service representative.