Paradyne 392xPLUS operation manual S85

Models: 392xPLUS

1 285
Download 285 pages 61.57 Kb
Page 210
Image 210

AT Command Set and S-Registers

Table 5-3

(10 of 12)

392xPlus S-Registers

S-Register

 

Description

DCP LCD

 

Command

 

 

 

Sequence

 

 

 

S85

Fast Disconnect. Register allows the modem to disconnect immediately after

Configure\Edit\

 

receiving a disconnect command from a local DTE or its own diagnostic

Line Dialer

 

control panel.

 

 

Register has the following values:

 

 

0

= Disable

 

 

1

= Enable

 

 

The factory setting is Disable.

 

 

 

 

S88

Straps When Disconnected. Register determines whether or not configuration

Configure\Edit\

 

options in the Active (Saved) configuration area are reloaded to Active

Misc

 

(Operating) when a disconnect occurs.

 

 

Register has the following values:

 

 

0 or 231 = No Change

 

 

1 or 232 = Reload

 

 

The factory setting is No Change.

 

 

 

 

 

S89

V.42

Automatic Request for Retransmission (ARQ) Window Size Increase.

 

 

Register allows the ARQ window size to be set to a value from six frames to

 

 

fifteen frames.

 

 

For best performance, this register should remain at its default setting of six

 

 

frames (ATS89 = 0). The only reason to change it is for satellite delays.

 

 

Register has the following values:

 

 

0

= six frames

 

 

1

= seven frames

 

 

2

= eight frames

 

 

3

= nine frames

 

 

4

= ten frames

 

 

5

= eleven frames

 

 

6

= twelve frames

 

 

7

= thirteen frames

 

 

8

= fourteen frames

 

 

9

= fifteen frames

 

 

The factory setting is 0 (six frames).

 

 

This command only applies when the modem connects using V.42bis data

 

 

compression or V.42 error control. If the modem is configured for Direct mode,

 

 

MNP mode, Buffer mode, or Synchronous operation, this command is ignored.

 

 

This command does not have a front panel equivalent.

 

 

 

 

S90

DTE Rate = VF. Register allows the DTE's data rate to be equal to the VF

Configure\Edit\

 

(telephone line) data rate. If Enabled, the data rate between the DTE and

DTE Interface

 

modem is the same as the modem's VF data rate. As a result, when the

 

 

modem is in Data mode, the speed of the data passed between the modem

 

 

and DTE occurs at the VF data rate.

 

 

Register has the following values:

 

 

0

= Disable

 

 

1

= Enable

 

 

The factory setting is Disable.

 

 

 

 

 

3920-A2-GN31-30

November 1996

5-25

Page 210
Image 210
Paradyne 392xPLUS operation manual S85